Status and high technology of diesel trash pump


    Compared with the traditional application of emergency power generation equipment and power distribution system to power the electric pump, the diesel engine is used to directly drive the fire pump and trash pump. The application in the fire protection field has unparalleled superiority. With the promotion of various high-tech, The change of design concept has promoted the use of diesel engine fire pumps in high-speed development of technical performance and application quantity, especially in modern high-rise buildings, industrial areas, residential areas, etc. The article further promotes the application of the fire fighting field to the diesel engine fire pump through the discussion of the new technical characteristics of the engine driven water pump.

    Key words

    Trailer mounted pump intelligent automation head flow rate
    1. Status of diesel engine irrigation pump
    1.1 defects in the old-fashioned emergency fire protection system
    1.1.1 The high-power diesel generator is used as the emergency generator set, and the power transmission and distribution system, the electric control cabinet and the dual-channel power conversion system are equipped to distribute the electric pump. The system is complex and difficult to maintain.
    1.1.2 Many fires are caused by electrical system failures. The fire distribution system may have failed in the fire alarm system, or the fire has destroyed the power distribution facilities, resulting in the fire protection system being unable to work.
    1.1.3 Equipment installation area is large, and capital construction investment is large.
    1.2 Advantages of diesel dewatering pump
    1.2.1 The power capacity of the relative power is greatly reduced, the system is simple, and the maintenance is convenient.
    1.2.2 System independence, reliability is greatly improved.
    1.2.3 Small size, the total investment is also greatly reduced.
    1.3 Control method and development direction of diesel engine irrigation pump
    1.3.1 manual type
    Manual start, manual speed control, manual monitoring.
    1.3.2 ordinary automatic type
    Acceptable fire signal self-starting, with basic protection (over temperature, over speed, under lubrication). The engine adopts mechanical speed regulation and starts at full speed. The static speed regulation rate is 5%~10%, and the dynamic speed adjustment speed is 10%~30%.
    1.3.3 Advanced Auto Type
    Acceptable fire signal self-starting or manual operation, with basic engine protection (over-temperature, over-speed, under-lubrication) using electronic speed control, idle speed / full speed selection, static adjustment rate can be 0, dynamic speed control rate is 3%~ 7%.
    1.3.4 Intelligent
    With manual, automatic, network remote control, automatic inspection and automatic fault diagnosis function, it can complete comprehensive state detection and running performance test separately with the central fire protection system, and start the operation process intelligent control - by microcomputer (hardware special chip for curing program) The electronic speed regulation of the command realizes soft start and soft rise speed, and has excellent static and dynamic speed regulation characteristics. The system can comprehensively monitor the engine's operating parameters and automatically diagnose the engine's faults, as well as monitor the pump's head, flow and power, so that the pump set can be reliably and comprehensively monitored. The intelligent system is not only fully functional, but also manufactured by a dedicated module, so it is small in size, high in reliability, and low in cost. It is the future direction of trailer mounted pump development.

    2. High-tech application of diesel trash pump
    2.1 Intelligent monitoring of the engine
    2.1.1 Control function
    2.1.2 The control system should have a fully automated control design, with control modes such as manual control, automatic program control, remote control, and forced start.
    2.1.3 can set various process control time of diesel engine, including - preheating or pre-lubrication time before start, start delay time, start limit time, start motor off speed, idle speed delay, soft speed increase process delay Time, idle cooling shutdown delay, etc.
    2.1.4 The rated speed value of the diesel engine can be arbitrarily set according to the need (because the user can change the engine speed to meet the requirements of the head and flow), and the speed of the engine during the start, idle speed, speed increase, full speed and other processes can be automatically monitored. Automatically complete the input and withdrawal of the starter motor (Intelligent judgment is caused by the start-up failure caused by the start-up motor and the start of the flywheel slip during the start-up process, or the start-up process is normal and the start-up fails. The former should immediately exit the start-up motor and try again after a while. Start, so as not to damage the starting gear and other components, the latter allows continuous start within a limited time, if a single start is unsuccessful, multiple times), too high speed and too low pre-alarm and over-limit shutdown.
    2.1.5 The alarm limit value can be set, and the items of pre-alarm such as over-limit pre-alarm (no stop), alarm and automatic stop at the same time should be included - overspeed, low speed, low lubricating oil pressure, high cooling temperature, low temperature ( Below 4°C anti-icing), low fuel level, low water level, low battery voltage, high battery voltage, uncalibrated speed signal, over-flow, etc.; items that automatically alarm and stop should include – no speed signal (start speed) Low, speed sensor failure, start motor slip), overspeed, low speed, low lube pressure, high cooling temperature, start failure, shutdown failure, oil pressure sensor open/short circuit, water temperature sensor open/short circuit, speed sensor open/short, flow Too big and overloaded.
    2.2 display function
    2.2.1 Diesel engine operating status display—According to the current actual situation of the system, the current state of the equipment is displayed—waiting, starting, fueling, starting, starting delay, idle delay, normal operation, cooling shutdown, emergency shutdown.
    2.2.2 Pump group operation parameter measurement display—In the system operation process, the current relevant parameter values ​​are displayedspeed, running time, fuel inventory, battery voltage, cooling temperature, lubricant pressure, pump outlet pressure, pump flow.
    2.2.3 Pump group alarm status display - When the system has a fault alarm, the panel can display the fault that occurred, indicating the type of alarm (pre-alarm or alarm) and the cause of the alarm.
    2.2.4 Pump group parameter setting display, display the current parameter values ​​of the system settings, including: start/stop process delay state setting value, running speed control setting value and all alarm and warning parameter setting values.
    2.2.5 Remote network monitoring function - Through the fire network communication system (or building automation system) to complete the system's tour detection (similar to the sense of temperature, smoke detection). It can control the unit to start/stop and analyze and archive its operating parameters. Because the fire protection system is usually in standby state for a long time, daily maintenance, maintenance, and system inspection are very important. The system can automatically test the standby state of the unit, timely pre-alarm, and ensure that the battery is in a good state.
    2.3 Product features and advancement
    To realize the automatic control and monitoring functions of the system, there are many parameters that need to be processed and controlled. It is impossible to implement data acquisition and logic control circuits composed of ordinary relays or discrete electronic components. Therefore, two systems are usually used internationally: 1 dedicated control module; 2 programmable controller. At present, it is common to use programmable controller (plc) for multi-channel analog (sensor transmitter), switch data acquisition and control (using plc: fast, can change the program at any time, easy to expand, but the system is still More complicated, and must be debugged by professional engineers, the price is relatively high).