Precautions
when purchasing a pump and precautions when using a diesel pump. The lower the
novice thinks, the smaller the diesel load. Under the misunderstanding of this
misunderstanding, when the pump is purchased, the lift of the pump is often
selected very high. In fact, for a self-priming
trash pump, when the pump model is determined, the power consumption is
proportional to the actual flow of the self-priming trash pump. The flow rate
of 6 inch trash pump will decrease with the increase of the lift, so the higher
the lift, the smaller the flow and the smaller the power consumption.
Conversely, the lower the lift, the greater the flow and the greater the power
consumed. Therefore, in order to prevent overload of the diesel engine, it is
generally required that the actual pumping use of the pump should not be less
than 60% of the nominal head. Therefore, when the high lift is used for low
lift pumping, the diesel engine is easily overloaded and high temperature or
black smoke. In severe cases, the diesel engine can be burned. If it is used in
an emergency, a gate valve (or a small outlet such as wood) should be installed
on the outlet pipe to reduce the flow, prevent the diesel engine from
overloading or reduce the diesel engine speed. Pay attention to the temperature
rise of the diesel engine. If the diesel engine is overheated, the flow rate of
the small outlet should be shut down or shut down. This is also easy to
misunderstand. Some operators think that blocking the water outlet and forcibly
reducing the flow will increase the diesel load. In fact, on the contrary, the
gate valve of the regular high-power centrifugal pump irrigation and drainage unit
is equipped with a gate valve. In order to reduce the diesel engine load when
the unit is started, the gate valve should be closed first. This is the reason
for the valve to be gradually opened after the diesel engine is started.
Large
diameter pump with small self priming sewage pump
Many
users think that this can improve the actual lift, in fact, the actual lift of
the pump = total lift - loss head. When the wet prime pump model is determined,
the total lift is certain; the loss head is mainly from the pipeline
resistance. The smaller the diameter, the greater the resistance, so the larger
the lift head is. Therefore, after the pipe diameter is reduced, the actual
lift of the pump cannot be increased. On the contrary, it will decrease,
resulting in a drop in pump efficiency. In the same way, when the small-diameter
6 inch trash pump is pumped with a large water pipe, the actual lift of the
water pump will not be lowered, but the loss head will be reduced due to the
decrease of the resistance of the pipeline, so that the actual lift is
improved. Some users think that when the small diameter pipe pump uses large
water pipes to pump water, it will inevitably increase the diesel engine load.
They think that the water in the outlet pipe will have a large pressure on the wet
prime pump impeller after the pipe diameter is increased, thus greatly
increasing the diesel engine load. As everyone knows, the magnitude of the
liquid pressure is only related to the height of the lift, and has nothing to
do with the cross-sectional area of the water
pipe. As long as the head is fixed, the impeller size of the pump is constant,
and the pressure acting on the impeller is constant regardless of the diameter
of the pipe. Only when the pipe diameter is increased, the water flow
resistance will decrease, and the flow rate will increase, and the power
consumption will also increase appropriately. However, as long as it is within
the rated head range, the pump can work normally regardless of the pipe
diameter, and it can also reduce the pipeline loss and improve the pump
efficiency.
When
installing the water inlet pipe, the horizontal section is horizontal or
upturned
This
will cause air to collect in the inlet pipe, reduce the vacuum of the water
pipe and the engine driven trash pump, and reduce the suction head of the pump
and reduce the amount of water. The correct way is: the horizontal section
should be slightly inclined to the water source, should not be horizontal, and
should not be lifted upwards.
More
elbows on the inlet pipe
If
there are many bends on the inlet pipe, it will increase the local flow
resistance. And the elbow should turn in the vertical direction, and it is not
allowed to turn in the horizontal direction to avoid collecting air.
The
water inlet of the engine driven trash pump is directly connected to the elbow
This
will result in uneven distribution of water as it passes through the elbow into
the impeller. When the inlet pipe diameter is larger than the wet prime pump
inlet, an eccentric reducer should be installed. The flat part of the eccentric
reducer is to be mounted on the upper part, and the inclined part is placed
below. Otherwise, the air will be collected, the amount of water will be
reduced or the water will not be pumped, and there will be a crash. If the
inlet pipe and the water inlet of the pump are equal in diameter, a straight
pipe shall be added between the water inlet and the elbow of the pump. The
length of the straight pipe shall not be less than 2 to 3 times the diameter of
the water pipe.
The
bottom section of the inlet pipe with the bottom valve is not vertical
If
installed in this way, the valve cannot be closed by itself, causing water
leakage. The correct installation method is: the inlet pipe with the bottom
valve, the bottom section is vertical. If it cannot be installed vertically due
to terrain conditions, the angle between the water pipe axis and the horizontal
plane should be 60° or more.
The
inlet of the inlet pipe is not in the right position.
(1)
The inlet of the inlet pipe is smaller than the diameter of the inlet from the
bottom of the pool and the wall of the pool. If there is dirt such as sediment
at the bottom of the pool, the distance from the bottom of the pool to the
bottom of the pool is less than 1.5 times the diameter, which will result in
poor water intake during pumping or inhalation of debris and blockage of the
water inlet.
(2)
When the water inlet of the inlet pipe is not deep enough, this will cause a
vortex on the water surface around the inlet pipe, affecting the inflow and
reducing the amount of water. The correct installation method is: the water
depth of the small and medium-sized water pump should not be less than 300 ~
600mm, and the large water pump should not be less than 600 ~ 1000mm.
The
outlet is above the normal water level of the outlet
If
the water outlet is above the normal water level of the water outlet, although
the pump lift is increased, the flow is reduced. If the water outlet must be
higher than the water level of the pool due to terrain conditions, the elbow
and short pipe should be installed at the nozzle to make the water pipe siphon
type and reduce the height of the water outlet.